Main Features :
Operating voltage range: DC11.0-18.0volt -
AC to DC adaptor (DC11.0-18V/5A)
Circuit power:Max.charge power 50W
Max.discharge power 5W
Charge current range:0.1-5.0A
Discharge current range:0.1-1.0A
Current drain for balancing Li-Po:300mAh/cell
Li-ion/Polymer cell count:1-6 series
Pb battery voltage:2V-20V
NiCd/NiMH battery cell count: 1-15cell
color:black
net weight:270g
unit size:132*80*24mm
packing weight:406g
packing size:163*112*40mm
Support battery:
NiCd / NiMH
Voltage level : 1.2V / cell
Allowable fast charge current : 1C-2C (depends on the performance of cell)
Discharge voltage cut off level : 0.85V / cell (NiCd), 1.0V / cell (NiMH)
Li-ion
Voltage level : 3.6V / cell
Max. charge voltage : 4.1V / cell
Allowable fast charge current : 1C or less
Discharge voltage cut off level:2.5v/cell or higher
LiPo
Voltage level : 3.7V / cell
Max. charge voltage : 4.2V / cell
Allowable fast charge current : 1C or less
Discharge voltage cut off level : 3.0V / cell or higher
LiFe
Voltage level : 3.3V / cell
Max. charge voltage : 3.6V y/ cell
Allowable fast charge current : 4C or less
Discharge voltage cut off level : 2.0V / cell or higher
Pb
Voltage level : 2.0V / cell
(Lead-acid) Max. charge voltage : 2.46V / cell
Allowable fast charge current : 0.4C or less
Discharge voltage cut off level : 1.75V / cell or higher
Features
*Optimized operating software
This charger features the so-called AUTO function that set the feeding current during the process of charging or discharging. Especially for Lithium batteries, it can prevent to overcharging which may lead to an explosion due to the user's fault. It can disconnect the circuit automatically and alarm once detecting any malfunction. All the programs of this product were controlled through two way linkage and communication, to achieve the maximum safety and minimize the trouble. All the settings can be configured by users.
*Internal independent Lithium battery balancer
This employs an individual-cell-voltage balancer. It isn't necessary to connect an external balancer for balance charging.
*Balancing individual cells battery discharging
During the process of discharging, B6 can monitor and balance each cell of the battery individually. Error message will be indicated and the process will be ended automatically if the voltage of any single one cell is abnormal.
*Adaptable to various type of lithium battery
This charger adaptable to various types of Lithium batteries, such as Li-ion, LiPo and the new LiFe series of batteries.
*Fast and storage mode of lithium battery
Purposes to charge Lithium battery variess, 'fast' charge reduce the duration of charging, whereas 'store' state can control the final voltage of your battery, so as to store for a long time and protect useful time of the battery.
*Maximum safety
Delta-peak sensitivity: The automatic charge termination program based on the principle of the Delta-peak voltage detection. When the battery's voltage exceeds the threshold, the process will be terminated automatically.
*Automatic charging current limit
You can set up the upper limit of the charging current when charging your NiCd or NiMH battery; it is useful for the NiMH battery of low impedance and capacity in the 'AUTO' charging mode.
*Capacity limit
The charging capacity is always calculated as the charging current multiplied by time. If the charging capacity exceeds the limit, the process will be terminated automatically when you set the maximum value.
*Temperature threshold
The battery's internal chemical reaction will cause the temperature of the battery to rise. If the temperature limit is reached, the process will be terminated.
*Processing time limit
You can also limit the maximum process time to avoid any possible defect.
*Input power monitoring
To protect the car battery used as DC input power from being damaged, its voltage keeps being monitored. If it drops below the lower limit, the process will be ended automatically
*Data store / load
The maximum five batteries's data can be stored for users' convenience. You can keep the data pertaining to program setting of the battery of continuous charging or discharging. Users can call out these data at any time without any special program setting.
*Cyclic charging / discharging
1 to 5 cyclic and continuous process of charge > discharge or discharge > charge is operable for battery refreshing and Balancing to stimulate the battery's activity.
|